24 Important Product Information
GFK-1671P
Problems Resolved
ID Description
hdrvsnp.exe process.
Resolution:
This problem is resolved in VersaPro 2.02.
19987
Unable to read Bulk Memory Area (BMA) size for 90-70 CPX CPUs
Details: After configuring BMA size>0 and storing the hardware configuration to PLC,
attempts to read BMA results in error “05E4 – Memory type for this selector does not exist”.
Resolution: This problem is resolved in VersaPro 2.02 and BMA size can be read.
Printing issues resolved:
21520
Printing problems with Fit to Page option on Win 9x Operating systems
Details: When a large VersaPro folder is printed on Win 9x OS, only a few pages will be
printed correctly. Then the font changes and becomes unreadable.
Resolution: This issue is resolved in VersaPro 2.02 and the printout will be generated
correctly for all the pages.
21687
VersaPro 2.01 locks up during Print Report on Win 9x Operating systems
Details: When printing a report from VersaPro 2.01, the application locks up and stops
responding.
Resolution: This issue is resolved in VersaPro 2.02 and the report will be generated.
Miscellaneous issues resolved:
ID Description
20233
Normalization error when loading logic with rungs of length 20 columns.
Details: When logic containing long rungs extending to 20 columns is loaded from PLC,
VersaPro displays a Normalization error message and the Load is stopped.
Resolution: This problem is resolved in VersaPro 2.02 and the block is loaded correctly.
19666
Syntax error when a VersaPro 1.5 folder or block with OVR_PRE system variable is
opened in VersaPro 2.0x.
Details: When a VersaPro 1.5 folder or block with system variable OVR_PRE is opened in
VersaPro 2.0x, a syntax error ‘System variable OVR_PRE is not supported by the specified
hardware’ is displayed.
Resolution: There are no errors in VersaPro 2.02.
16787
VersaPro Fax Registration Printing Problem due to Regional Settings
Details: The "Register via Fax" registration form cannot be printed out unless the Windows
Regional Settings is set to "English(United States)”.
Resolution: The registration form can be now printed with any Regional settings.
17856
VersaPro 2.01 or lower cannot connect over Ethernet on clean O/S
Details: When installing VersaPro 2.01 or lower onto a PC with a clean operating system with
no previous installation of VersaPro, VersaPro will not connect over the Ethernet. When one
attempts an Ethernet connection, the error message “Connect Error.0x0005 - Message Not Yet
Confirmed” is displayed.
Resolution: This is because the communication dlls are not correctly registered. They are
correctly registered in VersaPro 2.02 on install and VersaPro will connect over the Ethernet on
a clean operating system.
21468
VersaPro Online help has no information on Reserved words.
Resolution: A list of reserved words has been added to the VersaPro online help.
20565
Hardware Configuration options in different editions of VersaPro
Details: Hardware configuration types in VersaPro options-set (Tools->Options->Default
Hardware configuration) is available even for types which is not supported by the currently
installed edition of VersaPro. For example, 90-70 option is available for Standard edition also.
A user has Professional edition installed with 90-70 as the default Hardware confi
uration