August 2010
GFK-1671P
IMPORTANT PRODUCT INFORMATION
READ THIS INFORMATION FIRST
Product: VersaPro™ Programming Software Release 2.04
VersaPro Professional Edition (Supports Series 90™-70, 90-30, Micro, and VersaMax™ PLCs)
IC641VPH700E VersaPro Professional Edition - Single License, with Programming Cable
IC641VUG701E Logicmaster 90-70 Subscription to VersaPro Professional Edition Upgrade
IC641VUG703E VersaPro Standard Edition to VersaPro Professional Edition Upgrade
IC641VPP700E VersaPro Professional Edition - Single License
IC641VPP710E VersaPro Professional Edition 10 Pack
IC641VPP750E VersaPro Professional Edition 50 Pack
IC641VPP950E VersaPro Professional Edition 50 Seat Site License
IC641VPP999E VersaPro Professional Edition Unlimited Seat Site License
VersaPro Nano/Micro Edition (Supports Series 90 Micro and VersaMax Nano/Micro PLCs)
IC641VPS002H VersaPro Nano/Micro Edition – Single License
IC640VPS002H VersaPro Nano/Micro Edition - Single License, with Programming Cable
BC641VPN950C VersaPro Standard Edition 50 Seat Site License
BC641VPN999C VersaPro Standard Edition Unlimited Seat Site License
VersaPro Standard Edition (Supports Series 90-30, Micro, and VersaMax™ PLCs)
IC641VPH300L VersaPro Standard Edition - Single License, with Programming Cable
IC641VUG301L Logicmaster 90-30 Subscription to VersaPro Standard Edition Upgrade
IC641VPS300L VersaPro Standard Edition - Single License
IC641VPS305L VersaPro Standard Edition 5 Pack
IC641VPS310L VersaPro Standard Edition 10 Pack
IC641VPS325L VersaPro Standard Edition 25 Pack
IC641VPS350L VersaPro Standard Edition 50 Pack
IC641VPS950E VersaPro Standard Edition 50 Seat Site License
IC641VPS999E VersaPro Standard Edition Unlimited Seat Site License
VersaPro Demo Packs
IC641VPD010L VersaPro Distributor Demo 10 Pack
IC641VPD050L VersaPro Distributor Demo 50 Pack
IC641VPP050L VersaPro Media Kit - 50 Pack
VersaPro Tools
IC641VPSCAMA VersaPro CAM Editor
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - MPORTANT PRODUCT INFORMATION

August 2010 GFK-1671P IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST Product: VersaPro™ Programming Software Release 2.04 VersaPro Pro

Strona 2 - Minimum System Requirements

10 Important Product Information GFK-1671P Special Operational Notes Opening VersaPro 1.x created folders When opening VersaPro 1.x folders, the foll

Strona 3 - Operating Systems Supported

Important Product Information 11 GFK-1671P 6. For some 90-70 CPUs, you will need to update the hardware configuration before it will store correctly

Strona 4 - Installation

12 Important Product Information GFK-1671P Series 90-70 Features Not Supported in VersaPro The following Series 90-70 features are not supported in V

Strona 5 - VersaPro 2.03 New Features

Important Product Information 13 GFK-1671P Resolution: Add an ALW_ON contact in front of any single coil that has a vertical wire immediately in fro

Strona 6 - VersaPro New Features

14 Important Product Information GFK-1671P Installation Issues · After installing VersaPro 2.0x and then subsequently installing VersaPro 1.0x or 1.

Strona 7 - VersaPro 2.02 New Features

Important Product Information 15 GFK-1671P · When installing on Windows 95/98, you may receive the following error: “Isuninst has performed an ille

Strona 8 - VersaPro 2.01 New Features

16 Important Product Information GFK-1671P Profibus Issues Caution When using the 90-30 Profibus Master Module (HE693PBM101 or HE693PBM101F) with Ver

Strona 9 - Firmware Revision in

Important Product Information 17 GFK-1671P 2 If VersaPro crashes, some processes may remain in memory and need to be ended via the task manager. Det

Strona 10 - Special Operational Notes

18 Important Product Information GFK-1671P 3. Click on the I/O Config tab and check whether the Rack and Slot entries for all the Segments match the

Strona 11

Important Product Information 19 GFK-1671P Problems Resolved by Version 2.04 24338, 36286 Problem with reference address and length parameters for g

Strona 12 - Series 90 Micro Issues

2 Important Product Information GFK-1671P Caution You should back up VersaPro 1.x folders before installing VersaPro 2.04 because saving any of thes

Strona 13 - Equality Issues

20 Important Product Information GFK-1671P 34200 Error 502 comes up while validating projects with motion & local logic blocks Details: Few Vers

Strona 14 - Installation Issues

Important Product Information 21 GFK-1671P Problems Resolved by Version 2.03 Hardware issues resolved: 24498 VersaPro incorrectly reports a fatal ove

Strona 15

22 Important Product Information GFK-1671P Miscellaneous issues resolved: 24270 VersaPro online cross-reference and Use table reports do not specify

Strona 16 - Known Crashes or Lock Up

Important Product Information 23 GFK-1671P Problems Resolved by Version 2.02 Hardware issues resolved: 17581 GSD file import error Details: When impo

Strona 17 - Other Significant Issues

24 Important Product Information GFK-1671P Problems Resolved ID Description hdrvsnp.exe process. Resolution: This problem is resolved in VersaPro 2.

Strona 18

Important Product Information 25 GFK-1671P ID Description type. If he un-installs Professional and install Standard edition, he cannot create a folde

Strona 19

26 Important Product Information GFK-1671P Problems Resolved Problems Resolved by Version 2.01 Print issues resolved: ID Description CR74863/ CR72266

Strona 20

Important Product Information 27 GFK-1671P Communication issues resolved: ID Description 17024 Error when storing to UDR001 VersaMax Micro Details: W

Strona 21

28 Important Product Information GFK-1671P Problems Resolved ID Description 16880 A stop fault error is produced when the internal switch on ACC300 I

Strona 22

Important Product Information 29 GFK-1671P ID Description configuration, you may get an error stating that the data length should be 64 if you have c

Strona 23

Important Product Information 3 GFK-1671P Operating Systems Supported · Windows 95B · Windows 98 (First Edition Service Pack 1, Second Edition) ·

Strona 24 - Problems Resolved

30 Important Product Information GFK-1671P Problems Resolved Online Help issues resolved: ID Description 16661 Incorrect information in "Scan Se

Strona 25

Important Product Information 31 GFK-1671P Miscellaneous issues resolved: ID Description CR73125 VersaPro crashes when putting focus on Find/Replace

Strona 26

32 Important Product Information GFK-1671P Open Issues and Problems Open Issues and Problems Open issues in VersaPro 2.04 1. If you load a hardware

Strona 27

Important Product Information 33 GFK-1671P Open Issues and Problems Communications Issues ID Description Association of Device Feature in CCU Not Us

Strona 28

34 Important Product Information GFK-1671P Open Issues and Problems ID Description CR75914 Ethernet communications problems after upgrading to LM9070

Strona 29 - ID Description

Important Product Information 35 GFK-1671P Open Issues and Problems ID Description CR72374 Store of Program Logic that contains a large number of Jum

Strona 30

36 Important Product Information GFK-1671P Open Issues and Problems ID Description Insert of CAM blocks from other folders, Drag and Drop, Cut/Copy/

Strona 31

Important Product Information 37 GFK-1671P Open Issues and Problems Hardware Configuration Issues: ID Description CR71631 Incompatibility between MS

Strona 32 - Open Issues and Problems

38 Important Product Information GFK-1671P Open Issues and Problems ID Description CR74424 Loading autoconfigured VersaMax modules results in similar

Strona 33

Important Product Information 39 GFK-1671P Open Issues and Problems HMI Interaction Issues ID Description CR71605/ CR71607 DCOM for Windows 95 versio

Strona 34

4 Important Product Information GFK-1671P Installation Note VersaPro must be installed on a hard drive in your computer. Do not attempt to install Ve

Strona 35

40 Important Product Information GFK-1671P Open Issues and Problems Import of LM90 or Control Folder Issues ID Description CR71941/ CR71940/ CR71976

Strona 36

Important Product Information 41 GFK-1671P Open Issues and Problems ID Description CR73532 VersaPro will not Import 90-30 Control Folder. Details: Ve

Strona 37

42 Important Product Information GFK-1671P Open Issues and Problems ID Description CR73856 VersaPro 2.0x Imports Additional Variables from Control. D

Strona 38

Important Product Information 43 GFK-1671P Open Issues and Problems Installation/Licensing Issues: ID Description CR72511 Convert File system from FA

Strona 39

44 Important Product Information GFK-1671P Open Issues and Problems ID Description CR73149 VersaPro 1.0 appears non-functional if login profile used

Strona 40

Important Product Information 45 GFK-1671P Open Issues and Problems Internationalization Issues: ID Description CR73556 Can’t create configuration fo

Strona 41

46 Important Product Information GFK-1671P Open Issues and Problems Miscellaneous Issues ID Description CR74577 Grid Repainting issue when opening an

Strona 42

Important Product Information 47 GFK-1671P Open Issues and Problems Print Issues ID Description CR71970 Printing to HP8000 Series Printer Does Not w

Strona 43

48 Important Product Information GFK-1671P Open Issues and Problems Store/Load/Clear/Write Flash, EEPROM/Equality Issues ID Description CR71034 Failu

Strona 44

Important Product Information 49 GFK-1671P Open Issues and Problems ID Description CR72406 After storing a folder, the status reads Logic Not Equal.

Strona 45

Important Product Information 5 GFK-1671P VersaPro 2.03 New Features Series 90-30 Changes VersaPro 2.03 now supports the following Series 90-30 CPU:

Strona 46

50 Important Product Information GFK-1671P Open Issues and Problems ID Description CR75101 Cannot perform simultaneous loads from PLC to two differen

Strona 47

Important Product Information 51 GFK-1671P Open Issues and Problems ID Description CR72374 Store error for IL folder between 17.3 and 18K. Details: S

Strona 48

52 Important Product Information GFK-1671P Open Issues and Problems ID Description Logic/Configuration From and Registers parameters in Nano configu

Strona 49

6 Important Product Information GFK-1671P VersaPro New Features The following usability improvements are included in VersaPro 2.03: Usability Functio

Strona 50

Important Product Information 7 GFK-1671P VersaPro 2.02 New Features The following usability improvements are included in VersaPro 2.02: Usability Fu

Strona 51

8 Important Product Information GFK-1671P VersaPro 2.01 New Features VersaMax Nano/Micro Changes The following VersaMax Nano/Micro CPUs are supporte

Strona 52

Important Product Information 9 GFK-1671P The following VersaMax Nano/Micro Expansion Units are supported by VersaPro 2.01and 2.02: Description Ca