20 Important Product Information
GFK-1671P
34200
Error 502 comes up while validating projects with motion & local logic blocks
Details: Few VersaPro projects, which have valid motion and local logic blocks included threw
error 502 during validation.
Resolution: VersaPro 2.04 will not report this error for valid case.
34306
The font of print out increase in size from the second page onwards
Details: There were few instances where first page prints out correctly but from second page
onwards the font increases in size and cannot be read.
Resolution: This issue is fixed in VersaPro 2.04.
34362
Moving a CMM module in a 9070 destroys all EGD information associated
Details: Configure a CMM in a 9070 that has EGD information associated with it (exchanges
that use that CMM module) and move that CMM card in the hardware configuration, it erases
all EGD exchanges associated with it.
Resolution: EGD exchanges will not get deleted in VersaPro 2.04 after moving CMM to a
different slot.
35054
Not possible to enter negative constant to an input parameter of C block
Details: When we try to give negative constant as C block parameter an error was given as
"Constant Out of Range"..
Resolution: VersaPro 2.04 allows negative constant on C blocks.
35308
Run Mode Store of C Blocks is apparently not supported for the 90-70
Details: Run Mode Store of C Blocks is apparently not supported for the 90-70. The Message
Pops up and asks if you want to do a Stopped Mode Store. If you say Yes, it appears to
perform a Run Mode Store.
Resolution: In VersaPro 2.04, modified the check for C blocks during RMS to only ask about
stopped mode store if the PLC does not support bumpless RMS of C blocks.
35710
Maximum value for position offset for few APU functions is wrong
Details: Max value for Position offset value is 255 irrespective of APU function configured.
Resolution: This has been corrected in VersaPro 2.04. Max value varies depending upon APU
function configured.
36054
Save message box comes up for Variable Tables even when there are no modifications
Details: When you open projects created in earlier versions of VersaPro and close project
without any modifications. You will still receive a message to save variable tables.
Resolution: VersaPro 2.04 will not pop up this message in this type of scenarios.
39374
_Main.dec is not equal even though logic is equal
Details: Above problem is seen when we store logic, which has either BIT_SEQ or
SHFR_WORD function with ST set to either %M or %Q.
Resolution: This issue is fixed in VersaPro 2.04.
40448
No confirmation dialog when deleting an exchange
Resolution: VersaPro 2.04 will pop up a dialog to confirm the deletion of exchange.
40503
Moving CMM742 module and adding a module in that slot destroys EGD
Details: Configure EGD exchanges for CMM742 and move the module to another slot. Now,
add any module to the slot where CMM742 was previously present. EGD exchanges get
deleted.
Resolution: This issue has been fixed in VersaPro 2.04.
40590
“Output enable” parameter for GBI002 is not working properly
Details: This parameter has been incorrectly linked to discrete input segment. Parameter
should be attached to output segments
Resolution: This issue is fixed in VersaPro 2.04.